menor preço: € 43,66, preço mais alto: € 118,17, preço médio: € 61,82
(*)
Shahsiah, Ahmad: Mass Transfer in Electrical Insulation of Power Transformers / Modeling Migration of Characteristic Gases between Solid and Liquid Insulations / Ahmad Shahsiah / Taschenbuch / Englisch - Livro de bolso
[ED: Taschenbuch], [PU: VDM Verlag Dr. Müller], Dissolved Gas Analysis is one of the best known methods to detect incipient faults in power transformers. Characteristic gases for power tr… mais…
[ED: Taschenbuch], [PU: VDM Verlag Dr. Müller], Dissolved Gas Analysis is one of the best known methods to detect incipient faults in power transformers. Characteristic gases for power transformers are defined in IEC 60599. However, these gases migrate between the transformer liquid and solid insulation due to temperature variations; this could potentially cause errors in the fault detection method. Little analytical or experimental work has been performed to date on the temporal nature of this problem.The suggested dynamic model in this book is based on the process of diffusion. The steady-state information extracted from experiments is compared with findings obtained from the literature. The final dynamic model is tested against experiments.The results show that the migration phenomenon in the liquid-solid insulation of power transformers can be explained by diffusion equations. Other findings include diffusion coefficients and steady-state information of the characteristic gases in the transformer insulation system. This text..., DE, [SC: 0.00], Neuware, gewerbliches Angebot, 120, Banküberweisung, PayPal, Klarna-Sofortüberweisung, [CT: Sonstiges / Sonstiges]<
booklooker.de
Buchbär Custos de envio:Versandkostenfrei, Versand nach Deutschland. (EUR 0.00) Details...
(*) Livro esgotado significa que o livro não está disponível em qualquer uma das plataformas associadas buscamos.
Dissolved Gas Analysis is one of the best known methods to detect incipient faults in power transformers. Characteristic gases for power transformers are defined in IEC 60599. However, th… mais…
Dissolved Gas Analysis is one of the best known methods to detect incipient faults in power transformers. Characteristic gases for power transformers are defined in IEC 60599. However, these gases migrate between the transformer liquid and solid insulation due to temperature variations; this could potentially cause errors in the fault detection method. Little analytical or experimental work has been performed to date on the temporal nature of this problem. The suggested dynamic model in this book is based on the process of diffusion. The steady-state information extracted from experiments is compared with findings obtained from the literature. The final dynamic model is tested against experiments. The results show that the migration phenomenon in the liquid-solid insulation of power transformers can be explained by diffusion equations. Other findings include diffusion coefficients and steady- state information of the characteristic gases in the transformer insulation system. This text is suitable for researchers who work in the area of fault detection in high voltage fluid-filled equipment or students who are interested in mass transport phenomena. New Textbooks>Trade Paperback>Science>Engineering>ELEC Engr, VDM Verlag Core >1 >T<
BarnesandNoble.com
new in stock. Custos de envio:zzgl. Versandkosten., mais custos de envio Details...
(*) Livro esgotado significa que o livro não está disponível em qualquer uma das plataformas associadas buscamos.
[EAN: 9783639096590], Neubuch, [PU: VDM Verlag Dr. Müller], PHYSIK ASTRONOMIE, Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Dissolved G… mais…
[EAN: 9783639096590], Neubuch, [PU: VDM Verlag Dr. Müller], PHYSIK ASTRONOMIE, Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Dissolved Gas Analysis is one of the best known methods to detect incipient faults in power transformers. Characteristic gases for power transformers are defined in IEC 60599. However, these gases migrate between the transformer liqu., Books<
AbeBooks.de
moluna, Greven, Germany [73551232] [Rating: 4 (von 5)] NEW BOOK. Custos de envio: EUR 19.04 Details...
(*) Livro esgotado significa que o livro não está disponível em qualquer uma das plataformas associadas buscamos.
*Mass Transfer in Electrical Insulation of Power Transformers* - Modeling Migration of Characteristic Gases between Solid and Liquid Insulations / Taschenbuch für 48.99 € / Aus dem Bereic… mais…
*Mass Transfer in Electrical Insulation of Power Transformers* - Modeling Migration of Characteristic Gases between Solid and Liquid Insulations / Taschenbuch für 48.99 € / Aus dem Bereich: Bücher, Wissenschaft, Physik Medien > Bücher nein Buch (kartoniert) Hardcover;Naturwissenschaften, Medizin, Informatik, Technik;Physik, Astronomie, VDM Verlag Dr. Müller<
Hugendubel.de
Custos de envio:Shipping in 1-2 weeks, , Versandkostenfrei nach Hause oder Express-Lieferung in Ihre Buchhandlung., DE. (EUR 0.00) Details...
(*) Livro esgotado significa que o livro não está disponível em qualquer uma das plataformas associadas buscamos.
Mass Transfer in Electrical Insulation of Power Transformers / Modeling Migration of Characteristic Gases between Solid and Liquid Insulations / Ahmad Shahsiah / Taschenbuch / Englisch - Livro de bolso
[ED: Taschenbuch], [PU: VDM Verlag Dr. Müller], Dissolved Gas Analysis is one of the best known methods to detect incipient faults in power transformers. Characteristic gases for power tr… mais…
[ED: Taschenbuch], [PU: VDM Verlag Dr. Müller], Dissolved Gas Analysis is one of the best known methods to detect incipient faults in power transformers. Characteristic gases for power transformers are defined in IEC 60599. However, these gases migrate between the transformer liquid and solid insulation due to temperature variations; this could potentially cause errors in the fault detection method. Little analytical or experimental work has been performed to date on the temporal nature of this problem.The suggested dynamic model in this book is based on the process of diffusion. The steady-state information extracted from experiments is compared with findings obtained from the literature. The final dynamic model is tested against experiments.The results show that the migration phenomenon in the liquid-solid insulation of power transformers can be explained by diffusion equations. Other findings include diffusion coefficients and steady-state information of the characteristic gases in the transformer insulation system. This text..., DE, [SC: 0.00], Neuware, gewerbliches Angebot, 120, Banküberweisung, PayPal, Klarna-Sofortüberweisung, [CT: Sonstiges / Sonstiges]<
Custos de envio:Versandkostenfrei, Versand nach Deutschland. (EUR 0.00) Buchbär
Dissolved Gas Analysis is one of the best known methods to detect incipient faults in power transformers. Characteristic gases for power transformers are defined in IEC 60599. However, th… mais…
Dissolved Gas Analysis is one of the best known methods to detect incipient faults in power transformers. Characteristic gases for power transformers are defined in IEC 60599. However, these gases migrate between the transformer liquid and solid insulation due to temperature variations; this could potentially cause errors in the fault detection method. Little analytical or experimental work has been performed to date on the temporal nature of this problem. The suggested dynamic model in this book is based on the process of diffusion. The steady-state information extracted from experiments is compared with findings obtained from the literature. The final dynamic model is tested against experiments. The results show that the migration phenomenon in the liquid-solid insulation of power transformers can be explained by diffusion equations. Other findings include diffusion coefficients and steady- state information of the characteristic gases in the transformer insulation system. This text is suitable for researchers who work in the area of fault detection in high voltage fluid-filled equipment or students who are interested in mass transport phenomena. New Textbooks>Trade Paperback>Science>Engineering>ELEC Engr, VDM Verlag Core >1 >T<
new in stock. Custos de envio:zzgl. Versandkosten., mais custos de envio
[EAN: 9783639096590], Neubuch, [PU: VDM Verlag Dr. Müller], PHYSIK ASTRONOMIE, Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Dissolved G… mais…
[EAN: 9783639096590], Neubuch, [PU: VDM Verlag Dr. Müller], PHYSIK ASTRONOMIE, Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Dissolved Gas Analysis is one of the best known methods to detect incipient faults in power transformers. Characteristic gases for power transformers are defined in IEC 60599. However, these gases migrate between the transformer liqu., Books<
NEW BOOK. Custos de envio: EUR 19.04 moluna, Greven, Germany [73551232] [Rating: 4 (von 5)]
*Mass Transfer in Electrical Insulation of Power Transformers* - Modeling Migration of Characteristic Gases between Solid and Liquid Insulations / Taschenbuch für 48.99 € / Aus dem Bereic… mais…
*Mass Transfer in Electrical Insulation of Power Transformers* - Modeling Migration of Characteristic Gases between Solid and Liquid Insulations / Taschenbuch für 48.99 € / Aus dem Bereich: Bücher, Wissenschaft, Physik Medien > Bücher nein Buch (kartoniert) Hardcover;Naturwissenschaften, Medizin, Informatik, Technik;Physik, Astronomie, VDM Verlag Dr. Müller<
Custos de envio:Shipping in 1-2 weeks, , Versandkostenfrei nach Hause oder Express-Lieferung in Ihre Buchhandlung., DE. (EUR 0.00)
1Como algumas plataformas não transmitem condições de envio e estas podem depender do país de entrega, do preço de compra, do peso e tamanho do artigo, de uma possível adesão à plataforma, de uma entrega directa pela plataforma ou através de um terceiro fornecedor (Marketplace), etc., é possível que os custos de envio indicados pelo eurolivro não correspondam aos da plataforma ofertante.
Dados bibliográficos do melhor livro correspondente
Dissolved Gas Analysis is one of the best known
methods to detect incipient faults in power
transformers. Characteristic gases for power
transformers are defined in IEC 60599. However,
these gases migrate between the transformer liquid
and solid insulation due to temperature variations;
this could potentially cause errors in the fault
detection method. Little analytical or experimental
work has been performed to date on the temporal
nature of this problem.
The suggested dynamic model in this book is based on
the process of diffusion. The steady-state
information extracted from experiments is compared
with findings obtained from the literature. The
final dynamic model is tested against experiments.
The results show that the migration phenomenon in
the liquid-solid insulation of power transformers
can be explained by diffusion equations. Other
findings include diffusion coefficients and steady-
state information of the characteristic gases in the
transformer insulation system. This text is suitable
for researchers who work in the area of fault
detection in high voltage fluid-filled equipment or
students who are interested in mass transport
phenomena.
Dados detalhados do livro - Mass Transfer in Electrical Insulation of Power Transformers Ahmad Shahsiah Author
EAN (ISBN-13): 9783639096590 ISBN (ISBN-10): 3639096592 Livro de bolso Ano de publicação: 2008 Editor/Editora: VDM Verlag Core >1 >T 120 Páginas Peso: 0,195 kg Língua: ger/Deutsch
Livro na base de dados desde 2009-01-03T09:46:37+00:00 (Lisbon) Página de detalhes modificada pela última vez em 2024-01-13T10:10:25+00:00 (Lisbon) Número ISBN/EAN: 9783639096590
Número ISBN - Ortografia alternativa: 3-639-09659-2, 978-3-639-09659-0 Ortografia alternativa e termos de pesquisa relacionados: Autor do livro: ahmad Título do livro: transfer mass, electrical insulation, transformers more than